General information
Front door absorption refrigerators used for vaccines storage and freezing ice packs, in locations with unreliable power supply.
GE type works with either LPgas or electricity.
KE type works with either kerosene or electricity.
Standard type works with 230VAC/50Hz. Other voltages available on request. For other voltages (120 or 240 VAC) heating elements can be ordered separately.
Warning 1: On both types temperatures near the evaporator on the back wall of the refrigerating compartment are liable to fall below zero; this area is, therefore, not suitable for the storage of DPT, DT, TT and Hepatitis-B vaccine.
Warning 2: The kerosene type is equipped with a manually operated device that can be put in day or night position. It allows internal temperature to remain in the 0°C to 8°C interval, while outside temperature changes during the day/night cycle (32°C/15°C). If the device remains in position day during night time, the temperature inside is likely to fall below 0°C in places where night temperature is around or below 15°C.
Meets WHO/UNICEF Standard
Specifications
Specifications for the gas type (GE) and, in bracket, specifications for the kerosene type (KE)
|
Refrigerator |
Freezer |
Units |
Vaccine storage capacity |
55 (55) |
36 (36) |
litres |
Manufacturers gross volume |
170 (170) |
47 (47) |
litres |
External dimensions, H x W x L |
145x59x62 (165x59x59) |
— |
cm |
Performance at |
32 |
43 |
32 |
43 |
degrees C° |
Icepack freezing, with vaccine |
— |
— |
3.6(2.4) |
1.2(0.6) |
kg/24hrs |
Icepack freezing, without vaccine |
— |
— |
— |
— |
kg/hrs |
Holdover time during power cut |
3.0(3.6) |
1.5(2.4) |
— |
— |
hours |
Power consumption: electricity |
6.3 |
8.3 |
— |
— |
kWh/24 hrs |
Power consumption: gas |
0.6 |
0.8 |
— |
— |
lts/24 hrs |
Power consumption: kerosene |
(1.2) |
(1.4) |
— |
— |
lts/24 hrs |
Packed in a seaworthy plywood case.
Gas type (GE) supplied with 4 ice-trays, spare burner jet n°58, instruction manual and spare parts list.
Kerosene type (KE) supplied with standard package of essential spare parts for the Aladin 23E burner: 5 wicks, 3 wick cleaners, 3 lamp glasses, 1 lamp glass insert, 1 flue brush, 1 funnel, instruction manual, spare parts list.
Spare parts |
Part No. |
Price / unit |
Thermostat (gas/electric) |
200 71 99-04/1 |
CHF 39 |
Electric heater, 230VAC (gas/electric) |
17 37 42-24/8 |
CHF 21 |
Thermocouple (gas/electric) |
293 14 96-04/2 |
CHF 9 |
Safety valve (gas/electric) |
293 16 57-01/5 |
CHF 16 |
Burner jet No. 58 (gas/electric) |
200 74 19-21/7 |
CHF 8 |
Wick,cotton (kerosene/electric) |
289 00 62-00/9 |
CHF 9.5 |
Glass lamp (kerosene/electric) |
293 28 92-01/7 |
CHF 44.5 |
Flue baffle (kerosene/electric) |
293 03 77-01/1 |
CHF 12.5 |
Wick cleaner (kerosene/electric) |
289 00 65-00/2 |
CKF 6 |
Electric heater 230VAC (kerosene/electric) |
17 37 42-30/5 |
CHF 19 |
Flue brush (kerosene/electric) |
15 74 18-00/5 |
CHF 14.5 |