General information
Vaccines/Ice packs chest freezers.
Energy requirements: 220 VAC/50 Hz
Available in various voltages: 115, 240 VAC, 50 or 60 Hz.
Minimum of 8 hours electricity needed per 24 hours at 43°C
Meets WHO/UNICEF Standard
Voltage stabiliser recommended where power supply quality is not stable. Appliance equipped with HST compressor. The cooling refrigerant is R134A.
Specifications
Model: |
MF114 |
MF214 |
MF314 |
Units |
Vaccine storage capacity |
72 |
192 |
264 |
litres |
Manufacturer gross volume |
111 |
213 |
323 |
litres |
External dimensions, H x W x L |
85x60x72 |
85x60x113 |
85x60x156 |
cm |
Performance at 43°C |
|
|
|
|
Icepack freezing, with vaccine |
37.2/51 |
70.8/76 |
108/80 |
kg/hrs |
Icepack freezing, without vaccine |
17.5/24 |
22.86/24 |
32.4/24 |
kg/hrs |
Holdover time during power cut |
13 |
15.5 |
17.5 |
hours |
Power consumption: electricity |
1.58 |
1.93 |
2.71 |
kWh/24h |
Thermostat setting: Continuous energy |
6 |
3 |
3.5 |
|
Spare parts |
Part No. |
Price / unit |
Compressor, Danfoss FR8.5G OC |
03.603326 |
(CHF 118) |
Starting device (Relay) |
02.7038050 |
(CHF 11) |
Starting device (Capacitor) |
6520004 |
(CHF 18) |
Thermostat |
02.7038480 |
(CHF 11) |
Thermometer |
02.7020037-01 |
(CHF 12) |
Filter/drier type XH 9 (20 grs) |
02.6538053 |
(CHF 4.2) |
Alu-cylinder with R134A (1000 grs) |
04.9954073 |
(CHF 43) |
Basket for freezing ice packs |
02.3010195 |
(CHF 17) |