General information
Ice lined chest model compression refrigerators for vaccine storage.
Minimum of 8 hours electricity needed per 24 hours at 43°C°
Energy sources: 220 VAC/50 Hz. Also available in 115, 240 VAC, 50 or 60 Hz.
Voltage stabilizer recommended where power supply quality is not stable.
Warning : Temperature near the evaporator of the refrigerator is liable to fall below zero; this area is, therefore, not suitable for the storage of DPT, DT, TT and Hepatitis-B vaccine.
Meets WHO/UNICEF Standard
Appliance equipped with HST compressor. The cooling refrigerant is R134A
Specifications
Model |
MK144 |
MK204 |
MK304 |
Units |
Vaccine storage capacity, measured with vaccines baskets in place. |
45 |
63 |
108 |
litres |
Manufacturers gross volume, excludes the volume taken by the icelining. |
94 |
137 |
204 |
litres |
External dimensions, H x W x L |
85x70x72 |
85x60x92 |
85x60x126 |
cm |
Performance at |
32 |
43 |
32 |
43 |
32 |
43 |
degrees C° |
Icepack freezing, with vaccine |
— |
— |
— |
— |
— |
— |
kg/hrs |
Icepack freezing, without vaccine |
— |
— |
— |
— |
— |
— |
kg/hrs |
Holdover time during power cut
After intermittent power supply |
45 |
15 |
46 |
10 |
49 |
15 |
hours |
Power consumption: electricity |
0.47 |
1.07 |
0.6 |
1.41 |
0.8 |
1.67 |
kWh/24hrs |
Thermostat setting: Continuous energy |
6 |
6 |
7.5 |
7.5 |
7 |
7 |
|
Spare parts |
Part No. |
Price / unit |
Compressor, Danfoss TL5G (MK144) |
03.6038602 |
CHF 93 |
Compressor, Danfoss FR6G (MK204) |
03.6038754 |
CHF 102 |
Compressor, Danfoss FR8 5G (MK304) |
03.6038480 |
CHF 111 |
Starting device (Relay) |
02.7038089 |
CHF 11 |
Starting device (Capacitor) |
6520004 |
CHF 19 |
Electronic thermostat |
02.6520154 |
CHF 22 |
Thermometer |
02.7020037-01 |
CHF 12 |
Fan (MK304 |
02.6000902 |
CHF 25 |
Filter/drier type XH 9 (20 grs) |
02.6538053 |
CHF 4.2 |
Alu-cylinder with R134A (1000 grs) |
04.9954073 |
CHF 43 |
Basket for vaccine storage |
02.6938012 |