Surgical suture, absorbable, braided, Polyglactin 910

last updated : 2018/12/31
Code Description Budget Price Ship. weight Ship. vol.
MSNSABSB0R3
ABS, BRAID. VI, 0 US/3.5 E, 90 cm, n. 1/2-36.4 mm round, 346 CH 2.01 0.0046kg 0,028L Add
Controlled Temp : Storage +15 to +25°C
MSNSABSB1R3
ABS, BRAID. VI, 1 US/4 E, 90 cm, n. 1/2-39.9 mm round, 359 CH 2.01 0.005kg 0,028L Add
Controlled Temp : Storage +15 to +25°C
MSNSABSB20R2
ABS, BRAID. VI, 2-0 US/3 E, 90 cm, n. 1/2-25.9 mm round, 243 CH 2.01 0.005kg 0,028L Add
Controlled Temp : Storage +15 to +25°C
MSNSABSB20R3
ABS, BRAID. VI, 2-0 US/3 E, 75cm, n.3/8-30mm,round, gynec. CH 1.97 0.16kg 1,092L Add
Item to be justified
Controlled Temp : Storage +15 to +25°C
MSNSABSB20R3C
ABS, BRAID. VI, 2-0 US/3 E, 75cm, n.3/8-30mm cutting, gynec. CH 1.97 0kg 0 Add
Item to be justified
Controlled Temp : Storage +15 to +25°C
MSNSABSB2R4
ABS, BRAID. VI, 2 US/5 E, 90 cm, n. 1/2-48 mm round, 372 CH 2.01 0.2kg 1,0036L Add
Controlled Temp : Storage +15 to +25°C
MSNSABSB2RL
ABS, BRAID. VI, 2 US/5 E, 75 cm, n. 3/8-85 mm r., liver CH 2.80 0.007kg 0,042L Add
Controlled Temp : Storage +15 to +25°C
MSNSABSB30R1
ABS, BRAID. VI, 3-0 US/2 E, 70 cm, n. 1/2-18.5 mm round,2150 CH 2.16 0.0042kg 0,035L Add
Item to be justified
MSNSABSB30R2
ABS, BRAID. VI, 3-0 US/2 E, 70 cm, n. 1/2-21.8 mm round, 311 CH 1.97 0.0046kg 0,028L Add
Controlled Temp : Storage +15 to +25°C
MSNSABSB30R3
SUTURE, abs.brai. DEC2 (3/0), 3/8, 26mm, triang on request 0kg 0 Add
Controlled Temp : Storage +15 to +25°C
MSNSABSB40R1
ABS, BRAID. VI, 4-0 US/2 E, 70 cm, n. 1/2-18.5 mm round,2140 CH 1.97 0.0042kg 0,035L Add
Item to be justified
Controlled Temp : Storage +15 to +25°C
MSNSABSB60DS1
ABS, BRAID. VI, 6-0 US/0.7E, 45cm, dbl n.1/4-8.5mm, spa.,670 CH 5.69 0.07kg 0,5022L Add
Controlled Temp : Storage +15 to +25°C
MSNSABSBL0
ABS, BRAID. VI, LIGATURE 0 US/3.5 E, 140 cm, ref. 616 CH 2.10 0.0043kg 0,032667L Add
Controlled Temp : Storage +15 to +25°C
MSNSABSBL20
ABS, BRAID. VI, LIGATURE 2-0 US/3 E, 140 cm, ref. 615 CH 2.04 0.0042kg 0,032667L Add
Controlled Temp : Storage +15 to +25°C
MSNSABSBL30
ABS, BRAID. VI, LIGATURE 3-0 US/2 E, 140 cm, ref. 614 CH 1.95 0.0042kg 0,032667L Add
Controlled Temp : Storage +15 to +25°C

General information

Absorbable sutures includes:

  • Sutures (thread mounted in a needle) for joining the edges of a wound or incision by stitching.
  • Ligatures (thread without needle) used to tie up a bleeding artery.

Sutures for gastrointestinal, paediatric and general surgery:

MSNSABSB20R2:

ABS, BRAID. VI, 2-0 US/3 E, 90cm, n. &fraq12;-25.9mm round, 243

MSNSABSB2R4:

ABS, BRAID. VI, 2 US/5 E, 90cm, n. &fraq12;-48mm round, 372

MSNSABSB30R2:

ABS, BRAID. VI, 3-0 US/2 E, 70cm, n. &fraq12;-21.8mm round, 311

Sutures for urology and plastic surgery: Gauge USP 4-0:

MSNSABSB30R1:

ABS, BRAIDED VI, 3-0 US/2 E, 70cm, n. &fraq12;-18.5mm round,2150

MSNSABSB40R1:

ABS, BRAIDED VI, 4-0 US/2 E, 70cm, n. &fraq12;-18.5mm round,2140

Sutures for suturing muscles and fascia: Gauge USP 2, 1 and 0 (size 2 is also for suturing liver wounds

MSNSABSB2R4:

ABS, BRAIDED VI, 2 US/5 E, 90cm, n. &fraq12;-48mm round, 372

MSNSABSB2RL:

ABS, BRAIDED VI, 2 US/5 E, 75cm, n. 3/8 -85mm r., liver

MSNSABSB0R3:

ABS, BRAIDED VI, 0 US/3.5 E, 90cm, n. &fraq12;-36.4mm round, 346

MSNSABSB1R3:

ABS, BRAIDED VI, 1 US/4 E, 90cm, n. &fraq12;-39.9mm round, 359

Ligatures for tying off bleeding vessels: Gauge USP 0, 2-0 and 3-0

MSNSABSBL0:

ABS, BRAIDED VI., LIGATURE 0 US/3.5 E, 140cm, ref. 616

MSNSABSBL20:

ABS, BRAIDED VI., LIGATURE 2-0 US/3 E, 140cm, ref. 615

MSNSABSBL30:

ABS, BRAIDED VI., LIGATURE 3-0 US/2 E, 140cm, ref. 614

Specifications

Materials:

Thread: polyglactin 910 (copolymer composed of  90% glycoside and 10% L-lacticide)

 

Thread coating: mixture of equal parts copolymer of glycoside and lactide (polyglactin 370) and calcium stearate.

 

Needle: treated stainless steel.

 

A suture holds a wound together, in good apposition, until such time as the natural healing process is sufficiently well-advanced as to render support from suture materials unnecessary and redundant.

 

Thread: The absorbable synthetic sterile thread polyglactin 910 (e.g., EthiconVicryl a violet-dyed braided suture) elicits a minimal acute inflammatory reaction in tissue and minimal ingrowths of fibrous connective tissue.

 

Polyglactin 910 thread progressively loses tensile strength; absorption eventual occurs via hydrolysis: a process in which the copolymer degrades to glycolic and lactic acids that are subsequently absorbed and metabolized in the body.

 

Coating: Braided material is often coated to decrease capillarity and to create a smooth surface. Absorption begins as a loss of tensile strength followed by a loss of mass.

 

Vicryl; Indicated for use in general soft tissue approximation and/or ligation, including ophthalmic procedures, but not for use in vascular or neurological tissues.

Tensile strength:

Post implantation

 

- 50% at 21 days

 

- 0% at  35 days 

Absorption:

Essentially completed between 56 and 70 days.

                     

Vicryl Rapid: Indicated for use in soft tissue approximation of the skin and mucosa where only short-term support to a wound is required. Not intended for use in ligation, ophthalmic, cardiovascular or neurological procedures.

Tensile strength:

Post implantation

 

-50% at 5 days

 

-0% at  12 days

Absorption:

Essentially completed between 35 and 42 days.

 

The braid’s coated multifilament ensures ease of handling and knotting; the special lubricant coating remains bonded to the material throughout its use, ensuring the sutures smooth passage through tissue and easy knot tie-down.

 

Thread Gauge: as indicated in the Unite States Pharmacopoeia (USP) and the European pharmacopoeia (EP).

 

Gauges for absorbable and non-absorbable synthetic materials

 

USP size code

 

EP size code

 

Diameter

                       min.                       max.

                       5-0

                       1

                       0.10 – 0.14

                       4-0

                       1.5

                       0.15 – 0.19

                       3-0

                       2

                       0.20 – 0.24

                       2-0

                       2.5

                       0.25 – 0.29

                       0

                       3

                       0.30 – 0.39

                       1

                       4

                       0.40 – 0.49

                       2

                       5

                       0.50 – 0.59

 

Needles:

- Type: eyeless with attached needle, thread mounted on needle

 

- Point: round (non-cutting) has no edges that can cut through tissue; it is used for suturing easily torn tissues; i.e., peritoneum or intestine.

 

- Shape: the degree of curvature is described in terms of circumference: &fraq12; to 3/8 of a circle.

 

- Length: available in different lengths 18-48mm.

 

Key to read absorbable suture description

ABS, BRAIDED VI, 2-0 US/3 E, 90 cm, n. &fraq12;-25.9mm round, 243

General description:

Absorbable suture

ABS

Thread type

Braided

BRAID

Registered name:

Vicryl

VI

Thread Gauge:

US Pharmacopoeia

2-0 USP

 

European pharmacopoeia

3 EP

Tread length:

 

90cm

Needle:

 

n.

 

Shape: &fraq12; circle

&fraq12;

 

Length:

25.9

 

Point:

rounded (r.)

Manufacturer code Nr:

example: Ethicon V 243 H

243

Tensile strength post implantation is 0% at 35 days.

Absorption is completed between 56 and 70 days.

MSNSABSB2R4

MSNSABSB2RL

MSNSABSB0R3

MSNSABSB1R3

MSNSABSB20R2

MSNSABSB2R4

MSNSABSB30R2

MSNSABSBL0

MSNSABSBL20

MSNSABSBL30

Vicryl Rapid tensile strength post implantation is 0 % at 12 days.

Absorption is completed between 32 and 45 days.

MSNSABSB30R1

MSNSABSB40R1

Liver suture has a 3/8 needle with a blunt point

MSNSABSB2RL (Ref ASSUT 46468)

 

Unit presentation:

1 suture with needle or 1 ligature, sterile, double packaging, single-use.

Packaging:

Box containing 36 individually-packaged sutures or ligatures marked with the following:

 

- Product name and reference number.

 

- Product description and thread composition.

 

- Thread gauge size in USP and EP.

 

- Needle type and size.

 

- Sterile - Sterilization method (ethylene oxide).

 

- Expiration date, lot and batch number.

 

- CE mark and reference number of notifying body.

Storage:

Maximum temperature 25°C, protect from direct sunlight.

Comments:

Do not re-sterilize: once opened discard all unused sutures and ligatures.

 

Re-sterilizing causes materials to lose their strength and pliability.

Other:

 

Suture quality must meet the characteristics and tests described in the EU and US pharmacopoeias.

Must comply with European Medical Device Directive 93/42/EEC or American Directives 21CFR820.